{"title":"Heating Mantle Temperature Probes","description":"\u003cp\u003eA heating mantle temperature probe is a slim stainless steel sensor that plugs into a digital heating mantle and inserts directly into the reaction liquid, giving a true reading of the sample temperature rather than just the heater's own set point. This is what allows a digital mantle to hold a precise, repeatable temperature over the course of a reaction.\u003c\/p\u003e\u003cp\u003eSmartLabs stocks replacement and compatible temperature probes for digital heating mantles in South Africa, so a worn or inaccurate probe does not mean replacing the whole unit. Keeping a spare probe on hand is a simple way to avoid downtime on an active mantle during reflux, distillation, or synthesis work.\u003c\/p\u003e","products":[{"product_id":"mmsc-replacement-temperature-probe-1000ml","title":"MMSC Replacement Temperature Probe.","description":"\u003cp\u003eHigh \u003cspan class=\"a-list-item\" data-mce-fragment=\"1\"\u003eaccurate temperature measurement over a wide range with \u003c\/span\u003e\u003cspan class=\"a-list-item\" data-mce-fragment=\"1\"\u003e5 pin DIN connector.\u003c\/span\u003e\u003cspan class=\"a-list-item\" data-mce-fragment=\"1\"\u003eR eplacement part for external temperature control \u003c\/span\u003e\u003cspan data-product-sku=\"\"\u003eMMHM and \u003c\/span\u003e\u003cspan data-product-sku=\"\"\u003eMMSC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003ePlease note the probes are sensitive to aggressive acids. Please use a thermometer pocket when measuring the temperature of acids.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eTo safely measure the temperature of aggressive acids, avoid direct contact with the probe by using a protective thermometer pocket or a non-contact thermometer like an infrared thermometer or glass thermometer. These methods prevent the sensitive probe from corrosion and damage, ensuring accurate and safe temperature readings in harsh chemical environments.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"JOANLAB","offers":[{"title":"MMSC Replacement Temperature Probe - 250mL","offer_id":45693633003673,"sku":"HMSC-250ML-PRB","price":300.0,"currency_code":"ZAR","in_stock":true},{"title":"MMSC Replacement Temperature Probe - 500mL","offer_id":45693633069209,"sku":"HMSC-500ML-PRB","price":300.0,"currency_code":"ZAR","in_stock":true},{"title":"MMSC Replacement Temperature Probe - 1000mL","offer_id":45693632938137,"sku":"HMSC-1000ML-PRB","price":350.0,"currency_code":"ZAR","in_stock":true},{"title":"MMSC Replacement Temperature Probe - 2000mL","offer_id":45693632970905,"sku":"HMSC-2000ML-PRB","price":390.0,"currency_code":"ZAR","in_stock":true},{"title":"MMSC Replacement Temperature Probe - 5000mL","offer_id":45693633036441,"sku":"HMSC-5000ML-PRB","price":550.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0569\/3584\/1945\/files\/mmsc-replacement-temperature-probe-2297420.png?v=1756948364"},{"product_id":"temperature-probe-of-hs5c","title":"Temperature Probe of HS5C - Thermometer","description":"\u003cp\u003eThe Joanlab HS5C Temperature Probe is an external sensor used with the HS5C Digital Magnetic Stirrer to provide real-time, accurate monitoring of your liquid's temperature rather than just the heating plate's temperature. \u003c\/p\u003e\n\u003cdiv data-sn-op=\"2\" data-processed=\"true\"\u003e\n\u003cdiv class=\"otQkpb\" data-animation-nesting=\"\" data-sfc-cp=\"\" data-sfc-cb=\"\" data-complete=\"true\" data-sae=\"\"\u003e\u003cstrong class=\"Yjhzub\" data-sfc-cb=\"\" data-complete=\"true\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-sn-op=\"2\" data-processed=\"true\"\u003e\n\u003cul class=\"KsbFXc U6u95\" data-sfc-cb=\"\" data-complete=\"true\" data-processed=\"true\"\u003e\n\u003cli class=\"dF3vjf\" data-sfc-cb=\"\" data-hveid=\"CAEIBBAA\" data-complete=\"true\" data-sae=\"\"\u003e\u003cspan class=\"T286Pc\" data-sfc-cp=\"\" data-sfc-cb=\"\" data-complete=\"true\"\u003e\u003cstrong class=\"Yjhzub\" data-sfc-cb=\"\" data-complete=\"true\"\u003eSensor Type:\u003c\/strong\u003e \u003cstrong class=\"Yjhzub\" data-sfc-cb=\"\" data-complete=\"true\"\u003ePT1000\u003c\/strong\u003e resistance temperature detector (RTD).\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"dF3vjf\" data-sfc-cb=\"\" data-hveid=\"CAEIBBAB\" data-complete=\"true\" data-sae=\"\"\u003e\u003cspan class=\"T286Pc\" data-sfc-cp=\"\" data-sfc-cb=\"\" data-complete=\"true\"\u003e\u003cstrong class=\"Yjhzub\" data-sfc-cb=\"\" data-complete=\"true\"\u003eControl Range:\u003c\/strong\u003e Capable of controlling liquid temperatures up to \u003cstrong class=\"Yjhzub\" data-sfc-cb=\"\" data-complete=\"true\"\u003e280°C (536°F)\u003c\/strong\u003e.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"dF3vjf\" data-sfc-cb=\"\" data-hveid=\"CAEIBBAC\" data-complete=\"true\" data-sae=\"\"\u003e\u003cspan class=\"T286Pc\" data-sfc-cp=\"\" data-sfc-cb=\"\" data-complete=\"true\"\u003e\u003cstrong class=\"Yjhzub\" data-sfc-cb=\"\" data-complete=\"true\"\u003eAccuracy:\u003c\/strong\u003e Offers high precision with a display accuracy of \u003cstrong class=\"Yjhzub\" data-sfc-cb=\"\" data-complete=\"true\"\u003e±0.1°C\u003c\/strong\u003e and control accuracy of \u003cstrong class=\"Yjhzub\" data-sfc-cb=\"\" data-complete=\"true\"\u003e±1°C\u003c\/strong\u003e.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"dF3vjf\" data-sfc-cb=\"\" data-hveid=\"CAEIBBAD\" data-complete=\"true\" data-sae=\"\"\u003e\u003cspan class=\"T286Pc\" data-sfc-cp=\"\" data-sfc-cb=\"\" data-complete=\"true\"\u003e\u003cstrong class=\"Yjhzub\" data-sfc-cb=\"\" data-complete=\"true\"\u003eMaterial:\u003c\/strong\u003e Typically features a \u003cstrong class=\"Yjhzub\" data-sfc-cb=\"\" data-complete=\"true\"\u003estainless steel\u003c\/strong\u003e probe body for chemical resistance and durability.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv data-sn-op=\"2\" data-processed=\"true\"\u003e\n\u003cdiv class=\"otQkpb\" data-animation-nesting=\"\" data-sfc-cp=\"\" data-sfc-cb=\"\" data-complete=\"true\" data-sae=\"\"\u003e\u003cstrong class=\"Yjhzub\" data-sfc-cb=\"\" data-complete=\"true\"\u003eInstallation and Use\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-sn-op=\"2\" data-processed=\"true\"\u003e\u003col class=\"IaGLZe VimKh\" data-sfc-cb=\"\" data-complete=\"true\" data-processed=\"true\"\u003e\n\u003cli class=\"dF3vjf\" data-sfc-cb=\"\" data-hveid=\"CAEIBhAA\" data-complete=\"true\" data-sae=\"\"\u003e\u003cspan class=\"T286Pc\" data-sfc-cp=\"\" data-sfc-cb=\"\" data-complete=\"true\"\u003e\u003cstrong class=\"Yjhzub\" data-sfc-cb=\"\" data-complete=\"true\"\u003eConnection:\u003c\/strong\u003e Plug the probe into the dedicated \u003cstrong class=\"Yjhzub\" data-sfc-cb=\"\" data-complete=\"true\"\u003eexternal sensor port\u003c\/strong\u003e located on the rear of the HS5C unit.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"dF3vjf\" data-sfc-cb=\"\" data-hveid=\"CAEIBhAB\" data-complete=\"true\" data-sae=\"\"\u003e\u003cspan class=\"T286Pc\" data-sfc-cp=\"\" data-sfc-cb=\"\" data-complete=\"true\"\u003e\u003cstrong class=\"Yjhzub\" data-sfc-cb=\"\" data-complete=\"true\"\u003eMounting:\u003c\/strong\u003e Use the included \u003cstrong class=\"Yjhzub\" data-sfc-cb=\"\" data-complete=\"true\"\u003estainless steel bracket and clamp stand\u003c\/strong\u003e to hold the probe securely in your beaker or flask.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"dF3vjf\" data-sfc-cb=\"\" data-hveid=\"CAEIBhAC\" data-complete=\"true\" data-sae=\"\"\u003e\u003cspan class=\"T286Pc\" data-sfc-cp=\"\" data-sfc-cb=\"\" data-complete=\"true\"\u003e\u003cstrong class=\"Yjhzub\" data-sfc-cb=\"\" data-complete=\"true\"\u003ePositioning:\u003c\/strong\u003e Ensure the tip of the probe is immersed at least \u003cstrong class=\"Yjhzub\" data-sfc-cb=\"\" data-complete=\"true\"\u003e20mm\u003c\/strong\u003e into the liquid and remains \u003cstrong class=\"Yjhzub\" data-sfc-cb=\"\" data-complete=\"true\"\u003e5–10mm\u003c\/strong\u003e away from the vessel's bottom and walls to avoid false readings from the heating plate.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"dF3vjf\" data-sfc-cb=\"\" data-hveid=\"CAEIBhAD\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"T286Pc\" data-sfc-cp=\"\" data-sfc-cb=\"\" data-complete=\"true\"\u003e\u003cstrong class=\"Yjhzub\" data-sfc-cb=\"\" data-complete=\"true\"\u003eAutomatic Detection:\u003c\/strong\u003e Once connected, the digital display typically switches to show the \"Actual\" temperature from the probe (often indicated by a \"PROBE\" LED or icon).\u003c\/span\u003e\u003cspan class=\"uJ19be notranslate\" data-wiz-uids=\"wYSmU_25,wYSmU_26\" data-sfc-cb=\"\" data-complete=\"true\"\u003e\u003cspan class=\"vKEkVd\" data-animation-atomic=\"\" data-wiz-attrbind=\"class=wYSmU_24\/TKHnVd\" data-sae=\"\"\u003e \u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\u003c\/div\u003e","brand":"JOANLAB","offers":[{"title":"Default Title","offer_id":46072273240217,"sku":"HS5C-PRB","price":1000.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0569\/3584\/1945\/files\/cc6f32ce75a5372f2856b3c3b4fb05dd.png?v=1773507066"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0569\/3584\/1945\/collections\/heating-mantle-temperature-probes-3220825.webp?v=1782036342","url":"https:\/\/smartlabs.co.za\/collections\/heating-mantle-temperature-probes.oembed","provider":"SmartLabs","version":"1.0","type":"link"}